工业水处理 ›› 2006, Vol. 26 ›› Issue (3): 42-44. doi: 10.11894/1005-829x.2006年.26(03).42

• 试验研究 • 上一篇    下一篇

超临界水氧化法处理丙烯腈剧毒废水的实验研究

蔡毅1,5, 马承愚2, 彭英利3, 耿鹏印3, 田江霞3, 俞昌吉4   

  1. 1. 南京大学环境学院, 江苏, 南京 210093;
    2. 东华大学环境工程与科学学院, 上海 200051;
    3. 石家庄开发区奇力科技有限公司, 河北, 石家庄 050041;
    4. 吉化集团丙烯腈厂, 吉林市 132021;
    5. 深圳市福田区环境保护局, 广东, 深圳 518048
  • 收稿日期:2005-10-16 修回日期:2005-10-16 出版日期:2006-03-20 发布日期:2010-10-01
  • 作者简介:蔡毅(1979- ),2001 年毕业于哈尔滨工业大学,助理工 程师,在职硕士研究生。电话: 13714034101,E-mail: xiaoyi9818@sina.com。

Preliminary exploration for the treatment of wastewater from acrylonitrile production by supercritical water oxidation

Cai Yi1,5, Ma Chengyu2, Peng Yingli3, Geng Pengyin3, Tian Jiangxia3, Yu Changji4   

  1. 1. School of the Environment, Nanjing University, Nanjing 210093, China;
    2. School of Environmental Science and Engineering, Donghua University, Shanghai 200051, China;
    3. Shijiazhuang Development Region Qili Sci-Tech. Co., Ltd., Shijiazhuang 050041, China;
    4. Acrylonitrile Factory of Jilin Chemical Group Corporation, Jilin 132021, China;
    5. Futian Region Environmental Protection Burean of Shenzhen, Shenzhen 518048, China
  • Received:2005-10-16 Revised:2005-10-16 Online:2006-03-20 Published:2010-10-01

摘要:

丙烯腈生产过程中排放的废水为高浓度剧毒有机废水,采用焚烧等方法处理均不能满足环保要求。使用2.0L的超临界水氧化反应器对该废水进行处理实验研究。实验结果表明,当反应温度为650℃,压力为28MPa,氧气过量为理论量的200%,反应时间为180s时,COD最高去除率可达到99.998%。笔者考察了反应温度、压力、时间、氧气浓度以及催化剂等对COD去除率的影响。处理后出水水质中的COD、氢氰酸、色度、pH等指标均达到国家规定的《污水综合排放标准》。

关键词: 超临界水氧化, 丙烯腈, 废水处理, 高浓度有机废水

Abstract:

The wastewater from acrylonitrile production is highly concentrated, virulent and low biodegradable. Treating this kind of wastewater by using 2.0 L supercritical water oxidation reactor has been carried on. The results showthat when the reaction temperature is 650 ℃, the pressure is 28 MPa, oxygen excess is 200%, and the reaction time is 180 s, the highest COD removal rate can be up to 99.998%. The effects of reaction temperature, pressure, time, oxygen concentration and catalyst on the COD removal rate have been examined. The indexes of COD, hydrocyanic acid, chroma, pH value, etc. in the treated effluent water can meet the requirement ofthe national wastewater discharge standard.

Key words: supercritical water oxidation, acrylonitrile, wastewater treatment, highly concentrated organic wastewater