工业水处理 ›› 2016, Vol. 36 ›› Issue (5): 32-35. doi: 10.11894/1005-829x.2016.36(5).032

• 试验研究 • 上一篇    下一篇

过硫酸钠与双氧水催化降解印染废水的试验研究

许志至1, 徐岗2, 蒋素英2, 张波1   

  1. 1. 江苏大学环境与安全工程学院, 江苏镇江 212013;
    2. 艾特克控股集团有限公司, 江苏宜兴 214214
  • 收稿日期:2016-02-09 出版日期:2016-05-20 发布日期:2016-06-24
  • 通讯作者: 张波,副教授。E-mail:tabol@126.com。 E-mail:tabol@126.com
  • 作者简介:许志至(1991-),硕士。E-mail:865415231@qq.com。
  • 基金资助:

    国家科学支撑项目(2014BAC08B01)

Study on the catalytic degradation of dyeing wastewater by so-dium persulfate and hydrogen peroxide

Xu Zhizhi1, Xu Gang2, Jiang Suying2, Zhang Bo1   

  1. 1. School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013, China;
    2. ATK Holdings Group Co., Ltd., Yixing 214214, China
  • Received:2016-02-09 Online:2016-05-20 Published:2016-06-24

摘要:

为了考察Fe2+/Na2S2O8/H2O2氧化体系对实际印染废水的处理效果,首先试验确定Fe2+/H2O2和Fe2+/Na2S2O8氧化体系的最佳药剂投加量以及Fe2+/Na2S2O8/H2O2氧化体系的最佳pH,基于最佳pH条件下以药剂投加量为自变量,废水COD去除率为响应值,通过Box-Behnken设计方法设计试验,利用响应曲面分析优化,以优化结果为基础,改变氧化体系中药剂的投加时间与顺序,得出Fe2+/Na2S2O8/H2O2氧化体系最优工艺参数,经过90 min反应后,出水COD达到纺织染整行业废水排放限值。

关键词: Fenton氧化法, 过硫酸盐氧化法, 印染废水

Abstract:

To examine the treatment effect of Fe2+/Na2S2O8/H2O2 oxidation system on the actual dyeing wastewater,the optimum reagent dosage of Fe2+/H2O2 and Fe2+/Na2S2O8 oxidation system,as well as the optimum pH of Fe2+/H2O2 and Fe2+/Na2S2O8 oxidation system should be tested and determined firstly.Under the optimum pH condition,the reagent dosage is independent variable,and the wastewater COD removing rate is response value.Box-Behnken de-sign method is used for designing the tests,and response curved surface for analysis and optimization.Based on the optimum results,to change the reagent dosing time and sequence of the oxidation system.Thus,the best process parameters of Fe2+/Na2S2O8/H2O2 oxidation system are obtained.After reacted for 90 min,the effluent COD reaches the textile dyeing industry wastewater discharge limits.

Key words: Fenton oxidation, persulfate oxidation, dyeing wastewater

中图分类号: