摘要:
为研发工业锅炉脱硫除尘器废水回用处理新技术,构建了以多层叠合复合流沉淀技术为核心的絮凝沉淀处理中试系统。试验表明:当表面负荷u0≤4mm/s时,出水浊度平均值10度,最大值15度。随着表面负荷的增加,出水的浊度增加,但相对波动程度逐渐变小,绝对变化幅度增加。水量负荷冲击对系统处理效果的影响大于进水SS及pH的影响。
关键词:
多层叠合复合流沉淀,
脱硫除尘器,
废水回用
Abstract:
In order to study and develop the new technologies of recycling wastewater from desulphurization dustremoval for industrial boilers,a coagulation treatment pilot system has been constructed,the core of which is bysedimentation of multilayer & superimposed compound flow.The results show that the average turbidity in theeffluent is <10 degrees,and the maximum is <15 degrees,when the surface load u0≤4 mm/s.With the increasingof surface load,the turbidity in the effluent increases,but the relative degree of fluctuation reduces graduallyand the absolute amplitude of variation increases.The effect of water quantity load impact on the water treatmentefficiency is greater than the fluctuation of pH and SS of influent water.
Key words:
sedimentation of multilayer and superimposed compound flow,
desulphurization dust removalwastewater reuse
中图分类号:
南国英, 县银霞, 任淑萍, 王淑娜. 多层叠合复合流沉淀处理脱硫除尘器废水中试研究[J]. 工业水处理, 2009, 29(11): 31-34.