INDUSTRIAL WATER TREATMENT ›› 2008, Vol. 28 ›› Issue (4): 41-44. doi: 10.11894/1005-829x.2008.28(04).41

Previous Articles     Next Articles

Purifing metals-laden organic wastewater in three dimensional electrode bio-electro fixed-bed reaction tower

Wang Tao1, Li Xingang2, Du Qiyun3   

  1. 1. Key Lab of Hollow Fiber Membrane Materials and Membrane Process of Division of Education, Postdoctoral Station of Textile Science and Engineering, Tianjin Polytechnic University, Tianjin
    3. 00
    1.
    6. 0, China;
    2. National Engineering Research Center for Distillation Technology, Tianjin University, Tianjin
    3. 000
    7.
    2. , China;
    3. Motian Membrane Engineering and Technology Co., Ltd., Tianjin
    3. 00
    1.
    6. 0, China
  • Received:2007-10-16 Online:2008-04-20 Published:2010-10-01

电-生物反应塔处理含多种重金属离子的废水

王韬1, 李鑫钢2, 杜启云3   

  1. 1. 天津工业大学纺织科学与工程博士后流动站, 天津工业大学中空纤维膜材料与膜过程省部共建教育部重点实验室, 江西南昌 330060;
    2. 天津大学精馏技术国家工程研究中心, 天津 300072;
    3. 膜天膜工程技术有限公司, 天津 300160
  • 作者简介:王韬(1974- ), 2006 年毕业于天津大学, 获博士学位,E-mail:wangtao20000@eyou.com, 电话: 022-24528104。
  • 基金资助:

    天津市自然科学基金项目(07JCZJDC01400);中国博士后科学基金项目(20070410765)

Abstract:

In bio-electro fixed-bed reaction tower, the 3-dimension electrode balls have been used as biofilm carrier. The biofilm is covered with functional microbe acclimated by Cd2+, Pb2+ and Zn2+. In the intermittent experiment, Pb2+ and Zn2+ are best adsorbed at the voltage range of 3-4 V while Cd2+ at 4.5-5.5 V.Pb2+ and Zn2+ get to adsorption balance in 60 min, while Cd2+ in 120 min. Removal rates of all these three kinds of heavy metal ions decreases obviously with the increase of ionic initial concentration. After running for 15 h continuously, the adsorption balance of heavy metal ions to the reactor can be reached steadily. Compared with the intermittent water treatment method, the total amount of the heavy metal ions treated by the continuous process increase greatly. But it takes longer time to get to adsorption balance by the continuous process and its treatment effect is poorer.

Key words: bio-electro reaction tower, heavy metal ions, wastewater treatment

摘要:

经Cd2+、Pb2+及Zn2+驯化所得的功能混合菌,在陶瓷小球表面挂膜后置于电-生物反应器内。在间歇实验中,Pb2+和Zn2+的最佳处理电压在3~4V之间,而Cd2+在4.5~5.5V之间。吸附60min时,Pb2+和Zn2+达到了平衡,Cd2+在120min时达到平衡。随着初始浓度的增加,3种重金属离子的去除率都呈现明显的下降趋势。连续实验开始15h后,反应器对重金属离子的吸附达到稳定。同间歇处理废水方法相比,连续流程去除的重金属离子总量大大增加,但达到平衡的时间较长,且处理效果较差。

关键词: 电-生物反应塔, 重金属离子, 废水处理

CLC Number: