INDUSTRIAL WATER TREATMENT ›› 2014, Vol. 34 ›› Issue (4): 37-39. doi: 10.11894/1005-829x.2014.34(4).037

Previous Articles     Next Articles

Experimental research on the pretreatment of clindamycin wastewater by O3/H2O2 oxidation

Liu Yue, Gong Weijin   

  1. Zhongyuan University of Technology, Zhengzhou 450009, China
  • Received:2014-03-05 Online:2014-04-20 Published:2014-04-25

O3/H2O2氧化预处理克林霉素废水的实验研究

刘玥, 龚为进   

  1. 中原工学院, 河南郑州 450009
  • 作者简介:刘玥(1983-),博士,讲师。E-mail:yue5757@sina.com。
  • 基金资助:

    国家自然科学基金资助项目(51308561)

Abstract:

Clindamycin wastewater has been pretreated by O3/H2O2 process. Its oxygen uptake rate(OUR) has been used for evaluating the biodegradability of the treated wastewater. The effects of influential factors,such as amount of substance ratio of O3 and H2O2,pH,hydroxyl radical inhibitors etc. on the improvement of biodegradability of clindamycin wastewater by O3/H2O2 oxidation process are investigated. The results show that O3/H2O2 has greatly improved the wastewater biodegradability. Under the following conditions:n(H2O2): n(O3) is 0.9,and solution pH=10.5,OUR of the pretreated water could be increased from 0 to 0.45 mg/(g·min). In addition,it is indicated that hydroxyl radicals are the main factor in the process of O3/H2O2 pretreatment.

Key words: clindamycin, wastewater treatment, ozone oxidation

摘要:

以微生物的耗氧呼吸速率(OUR)为指标,从废水的可生化性出发,考察了O3与H2O2物质的量比、pH和羟基自由基抑制剂等因素对O3/H2O2氧化工艺提高克林霉素废水可生化性的影响。研究结果表明:O3/H2O2氧化工艺极大地提高了废水的可生化性,在n(H2O2):n(O3)为0.9、溶液pH为10.5 的条件下,废水OUR能够从0升高到0.45 mg/(g·min),同时还证实在O3/H2O2氧化过程中主要是羟基自由基发挥作用。

关键词: 克林霉素, 废水处理, 臭氧氧化

CLC Number: