Design of the modification project of a wastewater treatment plant for 2-nitro-paracresol production

Wang Jing   

  1. Juhui United Technology of Ecological and Environmental Protection Co., Ltd(. Jiang Su), Wuxi 214101, China
  • Received:2016-11-08 Online:2017-03-20 Published:2017-03-30

邻硝基对甲酚生产废水处理站的改造工程设计

王晶   

  1. 聚慧生态环保联合科技江苏有限公司, 江苏无锡 214101
  • 作者简介:王晶(1984—),硕士,工程师。电话:13914266808,E-mail:wangjing1984212@126.com。

Abstract:

Advanced oxidation technology,domestic sewage dilution,and aerobic technique combined technology have been applied to the modification project of a wastewater treatment plant for 2-nitro-paracresol production. In the wastewater,its pH is low and salinity is high. The operation results show that benzene ring in the wastewater containing 2-nitro-paracresol could effectively be broken and improve the biodegradability of the wastewater,when the addition of H2O2 is 5 kg/t and FeSO4·7H2O 6.8 kg/t. When HRT of UASB is 1.4 d,anoxia 1 d,and aerobic 1 d, the effluent COD of the pretreated wastewater is below 500 mg/L,reaching Level A standard specified in the Wastewater Quality Standards for Discharge to Municipal Sewers(CJ 343—2010)

Key words: 2-nitro-paracresol wastewater, advanced oxidation, fluidized bed, modification, engineering design

摘要:

将高级氧化技术、生活污水稀释与厌氧、好氧技术组合工艺应用于低pH、高含盐的含邻硝基对甲酚废水处理站改造工程,运行结果表明,当H2O2添加量为5 kg/t,FeSO4·7H2O的添加量为6.8 kg/t时可对含邻硝基对甲酚废水中的苯环有效断链,提高废水的可生化性。预处理后的废水在UASB停留时间1.4 d,缺氧、好氧停留时间均为1 d时,出水COD<500 mg/L,达到《污水排入城镇下水道水质标准》(CJ 343—2010)中A等级的标准。

关键词: 邻硝基对甲酚废水, 高级氧化, 流化床, 改造, 工程设计

CLC Number: