摘要:
对采用厌氧折流板反应器(ABR)处理难降解退浆废水的启动过程进行了研究.实验结果表明:经过90d的运行,反应器在32~34℃、上流速度8m/h、水力停留时间6d、COD容积负荷1.80kg/(m3.d)的条件下,COD去除率达到55%以上,启动成功.出水COD稳定在4500mg/L左右,碱度约为700~850mg/L.运行情况表明,启动初期反应器各隔室的pH变化较大,有效控制pH是系统启动成功的关键.启动后期,各隔室pH稳定在6.8~7.3之间,挥发性脂肪酸(VFA)质量浓度为300~500mg/L.随着隔室的横向推移,污泥的SS、VSS和SS/VSS不断增大,推测反应器中厌氧微生物相分离现象显著.
关键词:
厌氧折流板反应器,
难降解退浆废水,
生物处理
Abstract:
The start-up of anaerobic baffled reactor(ABR)for treating desizing wastewater has been studied.The results show that: after the start-up of the ABR has run for 90 d,and when the reactor is at 32-34 ℃,the upflow velocity is 8 m/h,the hydraulic retention time is 6 d and the volume loading is 1.80 kg/(m3·d),the COD removal rate is above 55%,the COD of outflow is about 4 500 mg/L, the alkalinity is between 700 mg/L to 850 mg/L.The running situation indicates that since the pH of each compartment at the early days of the start-up varies greatly, to control the pH efficiently is an important key of the start-up. At the latter days of the start-up,the pH of each compartment keeps stably from 6.8 to 7.3,and the concentration of volatile fatty acid(VFA)is from 300 mg/L to 500 mg/L.Along with the transverse process of compartments, the SS,VSS and SS/VSS of sludge grow greatly,it is predicted that anaerobic microorganism phases in the ABR has been separated distinctly.
Key words:
anaerobic baffled reactor,
refractorily degradable desizing wastewater,
biological treatment
中图分类号:
周建冬, 奚旦立, 李小琴, 刘荣荣. 厌氧折流板反应器处理退浆废水的启动研究[J]. 工业水处理, 2009, 29(7): 44-46,,47.
Zhou Jiandong, Xi Danli, Li Xiaoqin, Liu Rongrong. Start-up of the anaerobic baffled reactor for treating desizing wastewater[J]. INDUSTRIAL WATER TREATMENT, 2009, 29(7): 44-46,,47.