摘要:
采用反应与分离相耦合的途径,用19通道陶瓷膜元件构建了5L气升式膜反应器,并就其用于钢铁酸洗液的处理进行了研究。结果表明:在0.5~2.5m3/h曝气量范围内,稳定膜通量能维持在60L/(m2·h)以上,且提高曝气量有利于提高循环液体流速。在稳定操作条件下,料液中氢氧化铁悬浮物浓度、温度(1~45℃)和膜两侧压差(0.025~0.1MPa)均与膜通量呈线性关系。当处理Fe2+质量浓度为400mg/L的酸洗废液时,在溶氧度>70%、压差0.1MPa、18~25℃、pH为6~9、HRT=2h条件下,出水浊度2NTU,pH符合国家排放标准。
关键词:
多通道膜元件,
气升式反应器,
废水处理,
膜分离
Abstract:
Steel pickling waste has been treated by using a 5 L airlift membrane reactor which couples with a 19- channel porcelain membrane element.The results show that when the aeration volume is in the range of 0.5-2.5 m3/h, membrane flux can be maintained above 60 L/(m2·h).In addition,increasing the aeration amount is good for increasing the circulating liquid flux.Under stable operating conditions,the suspended solids concentration of ferric hydroxide in liquid,temperature(1-45 ℃) and operation pressure(0.025-0.1 MPa) show a linear relationship with membrane flux.Under the following conditions: Fe2+ mass concentration is 400 mg/L of pickling liquid waste,dissolved oxygen 70%,pressure difference 0.1 MPa,room temperature 18-25℃,pH 6-9,and the hydraulic retention time 2 h,the turbidity of effluent water is <2 NTU,pH accords with the national discharge standards.
Key words:
multi-channel membrane elementairlift reactorwastewater treatment,
membrane separation
中图分类号:
马江权, 陈云国, 王岚. 反应与分离相耦合的钢铁酸洗液处理研究[J]. 工业水处理, 2009, 29(11): 52-55.
Ma Jiangquan, Chen Yunguo, Wang Lan. Research on steel pickling wastewater treatment with membrane reactor coupling with membrane separation[J]. INDUSTRIAL WATER TREATMENT, 2009, 29(11): 52-55.